Ppol is a 3 nodes cluster featuring an hybrid HDD+SSD hard drive configuration and 10Gbps Ethernet.

The configuration of the hard drives is as follows:

  • the first hard drive is a 500 GB sata HDD. This drive hosts the system (kadeploy).
  • the second hard drives are 50GB sata SSD (MLC)

Those disks are connected to the system via a Raid Controller with does not provide JBOD. Hence, disks are configured as Raid0 logical disks with only one disk, so that they appear as /dev/sda, /dev/sdb in Linux. See megacli usage to change settings.

The network configuration is as follows:

  • eth0 is a 1Gbps NIC connected to Grid'5000 production network vlan (connected directly to the core router)
  • eth2 is a 10Gbps NIC connected to a dedicated VLAN (same a idkat) (via CIMENT's Dell 8024 Switch and then to the core router). No IP configuration is provided, so you need to do the setup manually, by yourself in a deploy job.
  • eth1 and eth3 have no link.

Configuration details

Disk configuration

Some notes for the configuration of the "JBOD"-like hard drives setup
ppol-3:~# cat <<EOF >> /etc/apt/sources.list
deb http://hwraid.le-vert.net/debian wheezy main
EOF

ppol-3:~# apt-get update
ppol-3:~# apt-get install --force-yes -y megacli

# Remove any foreign or previous configuration 
ppol-2:~# megacli -CfgForeign -Dsply -aall
ppol-2:~# megacli -CfgForeign -Clear -aall
ppol-2:~# megacli -CfgClr -aall

# The machines Raid Controller does not support JBOD. We must use the EachDskRaid0 mode, and disable cache.

ppol-2:~# megacli -CfgEachDskRaid0 WT NORA DIRECT -aall
                                    
Adapter 0: Created VD 0
Configured physical device at Encl-32:Slot-0.
Adapter 0: Created VD 1
Configured physical device at Encl-32:Slot-1.
Adapter 0: Created VD 2
Configured physical device at Encl-32:Slot-2.

3 physical devices are Configured on adapter 0.

Exit Code: 0x00
Misc
Adapter details
ppol-3:~# megacli -AdpAllInfo -aall
                                     
Adapter #0

==============================================================================
                    Versions
                ================
Product Name    : PERC H700 Integrated
Serial No       : 06A002M
FW Package Build: 12.3.0-0032

                    Mfg. Data
                ================
Mfg. Date       : 06/12/10
Rework Date     : 06/12/10
Revision No     : A02
Battery FRU     : N/A

                Image Versions in Flash:
                ================
BIOS Version       : 3.09.00
FW Version         : 2.30.03-0872
Preboot CLI Version: 04.02-004:#%00008
Ctrl-R Version     : 2.02-0009
NVDATA Version     : 2.03.0053
Boot Block Version : 2.02.00.00-0000
BOOT Version       : 01.250.04.219

                Pending Images in Flash
                ================
None

                PCI Info
                ================
Controller Id	: 0000
Vendor Id       : 1000
Device Id       : 0079
SubVendorId     : 1028
SubDeviceId     : 1f17

Host Interface  : PCIE

Link Speed 	     : 0 
Number of Frontend Port: 0 
Device Interface  : PCIE

Number of Backend Port: 8 
Port  :  Address
0        4433221105000000 
1        4433221106000000 
2        4433221107000000 
3        0000000000000000 
4        0000000000000000 
5        0000000000000000 
6        0000000000000000 
7        0000000000000000 

                HW Configuration
                ================
SAS Address      : 5842b2b014b22d00
BBU              : Present
Alarm            : Absent
NVRAM            : Present
Serial Debugger  : Present
Memory           : Present
Flash            : Present
Memory Size      : 512MB
TPM              : Absent
On board Expander: Absent
Upgrade Key      : Absent
Temperature sensor for ROC    : Absent
Temperature sensor for controller    : Absent


                Settings
                ================
Current Time                     : 13:41:25 7/15, 2014
Predictive Fail Poll Interval    : 300sec
Interrupt Throttle Active Count  : 16
Interrupt Throttle Completion    : 50us
Rebuild Rate                     : 30%
PR Rate                          : 30%
BGI Rate                         : 30%
Check Consistency Rate           : 30%
Reconstruction Rate              : 30%
Cache Flush Interval             : 4s
Max Drives to Spinup at One Time : 4
Delay Among Spinup Groups        : 12s
Physical Drive Coercion Mode     : 128MB
Cluster Mode                     : Disabled
Alarm                            : Disabled
Auto Rebuild                     : Enabled
Battery Warning                  : Enabled
Ecc Bucket Size                  : 15
Ecc Bucket Leak Rate             : 1440 Minutes
Restore HotSpare on Insertion    : Disabled
Expose Enclosure Devices         : Disabled
Maintain PD Fail History         : Disabled
Host Request Reordering          : Enabled
Auto Detect BackPlane Enabled    : SGPIO/i2c SEP
Load Balance Mode                : Auto
Use FDE Only                     : Yes
Security Key Assigned            : No
Security Key Failed              : No
Security Key Not Backedup        : No
Default LD PowerSave Policy      : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 0 
Auto Enhanced Import             : No
Any Offline VD Cache Preserved   : No
Allow Boot with Preserved Cache  : No
Disable Online Controller Reset  : No
PFK in NVRAM                     : No
Use disk activity for locate     : No
POST delay			 : 90 seconds
BIOS Error Handling          	 : Stop On Errors
Current Boot Mode 		  :Normal
                Capabilities
                ================
RAID Level Supported             : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives                 : SAS, SATA

Allowed Mixing:

Mix in Enclosure Allowed

                Status
                ================
ECC Bucket Count                 : 0

                Limitations
                ================
Max Arms Per VD          : 32 
Max Spans Per VD         : 8 
Max Arrays               : 128 
Max Number of VDs        : 64 
Max Parallel Commands    : 1008 
Max SGE Count            : 60 
Max Data Transfer Size   : 8192 sectors 
Max Strips PerIO         : 42 
Max LD per array         : 16 
Min Strip Size           : 8 KB
Max Strip Size           : 1.0 MB
Max Configurable CacheCade Size: 0 GB
Current Size of CacheCade      : 0 GB
Current Size of FW Cache       : 0 MB

                Device Present
                ================
Virtual Drives    : 3 
  Degraded        : 0 
  Offline         : 0 
Physical Devices  : 4 
  Disks           : 3 
  Critical Disks  : 0 
  Failed Disks    : 0 

                Supported Adapter Operations
                ================
Rebuild Rate                    : Yes
CC Rate                         : Yes
BGI Rate                        : Yes
Reconstruct Rate                : Yes
Patrol Read Rate                : Yes
Alarm Control                   : Yes
Cluster Support                 : No
BBU                             : Yes
Spanning                        : Yes
Dedicated Hot Spare             : Yes
Revertible Hot Spares           : Yes
Foreign Config Import           : Yes
Self Diagnostic                 : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares               : Yes
Deny SCSI Passthrough           : No
Deny SMP Passthrough            : No
Deny STP Passthrough            : No
Support Security                : Yes
Snapshot Enabled                : No
Support the OCE without adding drives : Yes
Support PFK                     : No
Support PI                      : No
Support Boot Time PFK Change    : No
Disable Online PFK Change       : No
Support Shield State            : No
Block SSD Write Disk Cache Change: No

                Supported VD Operations
                ================
Read Policy          : Yes
Write Policy         : Yes
IO Policy            : Yes
Access Policy        : Yes
Disk Cache Policy    : Yes
Reconstruction       : Yes
Deny Locate          : No
Deny CC              : No
Allow Ctrl Encryption: No
Enable LDBBM         : Yes
Support Breakmirror  : No
Power Savings        : No

                Supported PD Operations
                ================
Force Online                            : Yes
Force Offline                           : Yes
Force Rebuild                           : Yes
Deny Force Failed                       : No
Deny Force Good/Bad                     : No
Deny Missing Replace                    : No
Deny Clear                              : No
Deny Locate                             : No
Support Temperature                     : No
NCQ                                     : No
Disable Copyback                        : No
Enable JBOD                             : No
Enable Copyback on SMART                : No
Enable Copyback to SSD on SMART Error   : No
Enable SSD Patrol Read                  : No
PR Correct Unconfigured Areas           : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares         : No
Spin Down time                          : 30 
T10 Power State                         : No
                Error Counters
                ================
Memory Correctable Errors   : 0 
Memory Uncorrectable Errors : 0 

                Cluster Information
                ================
Cluster Permitted     : No
Cluster Active        : No

                Default Settings
                ================
Phy Polarity                     : 0 
Phy PolaritySplit                : 0 
Background Rate                  : 30 
Strip Size                       : 64kB
Flush Time                       : 4 seconds
Write Policy                     : WB
Read Policy                      : Adaptive
Cache When BBU Bad               : Disabled
Cached IO                        : No
SMART Mode                       : Mode 6
Alarm Disable                    : Yes
Coercion Mode                    : 128MB
ZCR Config                       : Unknown
Dirty LED Shows Drive Activity   : No
BIOS Continue on Error           : 0 
Spin Down Mode                   : None
Allowed Device Type              : SAS/SATA Mix
Allow Mix in Enclosure           : Yes
Allow HDD SAS/SATA Mix in VD     : No
Allow SSD SAS/SATA Mix in VD     : No
Allow HDD/SSD Mix in VD          : No
Allow SATA in Cluster            : No
Max Chained Enclosures           : 1 
Disable Ctrl-R                   : No
Enable Web BIOS                  : No
Direct PD Mapping                : Yes
BIOS Enumerate VDs               : Yes
Restore Hot Spare on Insertion   : No
Expose Enclosure Devices         : No
Maintain PD Fail History         : No
Disable Puncturing               : No
Zero Based Enclosure Enumeration : Yes
PreBoot CLI Enabled              : No
LED Show Drive Activity          : Yes
Cluster Disable                  : Yes
SAS Disable                      : No
Auto Detect BackPlane Enable     : SGPIO/i2c SEP
Use FDE Only                     : Yes
Enable Led Header                : No
Delay during POST                : 0 
EnableCrashDump                  : No
Disable Online Controller Reset  : No
EnableLDBBM                      : Yes
Un-Certified Hard Disk Drives    : Allow
Treat Single span R1E as R10     : Yes
Max LD per array                 : 16
Power Saving option              : All power saving options are disabled
Default spin down time in minutes: 30 
Enable JBOD                      : No
Time taken to detect CME         : 60s

Exit Code: 0x00
logical disks details
ppol-3:~# megacli -ldinfo -lall -aall
                                     

Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 465.25 GB
Sector Size         : 512
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No


Virtual Drive: 1 (Target Id: 1)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 46.0 GB
Sector Size         : 512
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No


Virtual Drive: 2 (Target Id: 2)
Name                :
RAID Level          : Primary-0, Secondary-0, RAID Level Qualifier-0
Size                : 46.0 GB
Sector Size         : 512
Parity Size         : 0
State               : Optimal
Strip Size          : 64 KB
Number Of Drives    : 1
Span Depth          : 1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy   : Disk's Default
Encryption Type     : None
Bad Blocks Exist: No
Is VD Cached: No



Exit Code: 0x00